1, the application
Inside the thermocouple used stuck accidentally silk, thoroughly to prevent oil spill or leak. Applicable to the production site of high wear-resistant solid particles or fluid, is indispensable to the refinery temperature measuring device.
2, main technical parameters
Electrical exports: M20X1. 5 npt1/2
Wear-resisting head hardness: HRC62-65
Protection grade: IP65
Level of flame-proof: d lots BT4, d lots CT5
Nominal pressure: 2.5 MPa
Type and specification
Type, index, thermal response time measuring range LX1 protection tube material specifications
WRN - 430 - m
WRN2 0-800-430 - m K < 1 cr18ni9ti 180 s
450 x300
500 x350
550 x400
600 x450
650 x500
750 x600
950 x800
1150 x1000
WRE - 430 - m
WRE2-430 - m E 0-600
WRN - 440 - m
WRN2 0-800-440 - m K
WRE - 440 - m
WRE2-440 - m E 0-600