Industrial flame-proof platinum resistance is a kind of temperature sensor. A wide application in industrial control system, through the temperature sensor, can control the temperature of the object parameter into electrical signal, passed to the display, record and monitoring instrument, testing, adjusting and control law in the system. In chemical plant, the production site is often accompanied by various kinds of flammable, explosive chemical gas, steam, if use common platinum resistance is not safe, easy to environment caused by gas explosion. On these occasions, therefore, must use the flame-proof thermocouples as temperature sensor, the factory production of flame-proof platinum resistance product is used in d II BT4 ~ d category II CT6 temperature interval explosive gases in dangerous places. Our factory produce flame-proof thermocouple adopts imported components for thermal components, its technical performance in line with the ZBY301-85 industrial platinum electrical technical conditions and indexing table. At the same time products conform to the general requirements for explosive environment with explosion-proof electrical equipment, GB3836.2 GB3836.1-83-83 standard.
Mixer main technical indicators
Range specifications
model
Degree,
℃ temperature range
Precision grade
The allowable deviation delta t ℃
WZP
WZP 2
WZPK
WZPK 2
PT100-200 ~ 500 grade A + (0.15 + 0.002 | t |)
B + (0.30 + 0.005 | t |)
Note: the "t" for the thermal components measured temperature of absolute value, class B double platinum resistance to only supply
Thermal resistance allowed by current
Through platinum resistance measured current is not more than 5 ma.
Explosion-proof type and level group
Explosion-proof grade groups: d II BT4 or d CT4 II; D II II CT6 BT6 or d
Enclosure protection grade: IP54
The principle of structure
Flame-proof thermal resistance fabricated thermal resistance of the structure, principle and basic same, SuoOu is, explosion-proof products on the junction box (shell) in the design of the structure of the flameproof special, junction box with high strength aluminum alloy die casting, and have enough internal space, thickness and mechanical strength, thermal stability of the rubber sealing ring conform to the state explosion protection standard. So, when the junction box of internal explosive mixed gas explosion, it won't destroy junction box, and the resulting heat cannot spread outward - explosive.
Because the explosion-proof products adopt special structure, make the product completely conforms to use d II BT4 to d II CT6 explosion-proof group interval temperature range, as long as the user strictly abide by the regulations regarding the use of the product, the product can achieve reliable explosion-proof effect.
Electrical equipment's type, level and temperature category description:
Electrical equipment is divided into two categories: type I, the coal mine electrical equipment;
Class II - use electrical equipment factory
Explosion-proof grade
Flame-proof heat resistance level of explosion-proof mechanical its biggest security clearance is suitable for explosive gas mixture is divided into A, B, C level 3.
Temperature classes
Flame-proof tropical resistance according to the exposed part of the maximum surface temperature can be divided into temperature classes T1 ~ T6 six groups.
Types and specifications of the flame-proof resistance
Category type dividing ℃ temperature range protection tube
Materials thermal response t0.5 s time nominal pressure Mpa explosive-proof grade structure characteristic specifications
Total length L (mm) deep L (mm)
Platinum thermal resistance WZP - 24 sa PT100 1 cr18ni9ti stainless steel - 200 ~ 200
Or 0 cr18ni
12 m02ti 90 or less 10 explosion-proof junction box fixed screw M27 * 2 explosion-proof junction box fixed flange installation 250 350 400 450 350 650 900 1150 100 400 250 300 400 500 300 1000 d IIBT4
D II BT6 or
D II CT4
D II CT6
WZP2-24 sa
WZP - 44 sa
6.4
WZP2-44 sa
WZP - 64 - s
WZP2
1 cr18ni9ti 30 conical protection tube M33 * 2, 250, 350, 450, 100, 200, 300
Flame-proof armored thermal resistance and the kinds of specifications
Category model points
The degree of
Temperature of no.
℃ range of protecting tube
Diameter D
Time (mm) thermal response t0.5 s nominal pressure structure of Mpa
Features specifications for explosion-proof
level
The total length L
(mm) deep l
(mm)
Platinum thermal resistance WZPK - 24
WZPK2-24
PT100-200 -
Phi 500 6
or
Phi 5
12 or less
8 of 10 or less
Explosion-proof junction box fixed screw to install M27 * 2
300
350
450
550
650
900
1150
150
200
300
400
500
750
1000
D IIBT4
D IIBT6
or
D IICT4
D IICT6
WZPK - 44
6.4 WZPK2-44
Explosion-proof junction box fixed flange installation