use
This product is suitable for the coal mine mobile transformer and similar devices with copper core rubber insulated metal shielding monitoring type flexible cable.
Conditions of use
Cable conductor long-term allowed working temperature is 90 ℃.
The minimum bending radius of cable is 6 times of cable diameter.
The earth wire of the cable core must be well grounded.
Model, name, purpose and size
Model that USES
MYPTJ - 3.6/6 coal mine mobile metal shield monitoring type rubber set soft cable of rated voltage 3.6/6 kv transformer and underground mobile
Similar devices of power supply connection.
MYPTJE - 3.6/6 type coal mine mobile metal shielding monitoring elastomer soft cable
Some conclusions by nominal cross section conductor (was) nominal thickness (mm) cable diameter (mm)
Power line core earth core core power line core insulation monitoring line
(mm) monitoring wire core sheathed MYPTJ - 3.6/6
3.6/6 MYPTJE -
The minimum maximum
3 x 3 x 25 16/3 3 x 2.5 2.5 2.5
5.5 57.5 63.0
3 x 3 x 35 16/3 3 x 2.5 2.5 2.5
5.5 62.5 68.6
3 x 3 x 50 25/3 3 x 2.5 2.5 2.5
5.5 64.9 71.4
Note: 1) inner sheath thickness calculation does not make the appraisal
Power line core conductor nominal section (was) power line core 20 ℃ (M Ω. Km) insulation resistance monitoring wire core insulation resistance of 20 ℃ (M Ω. Km)
25 p 650 5 or higher
35 p 550 5 or higher
50 or 500 or greater